Components for Buildings with Thatched Roof
Lightning protection system components for buildings with thatched roofs.
Air-termination conductors on thatched roofs have to be installed at a distance to the roof, e.g. on isolating supports. Certain distances also have to be kept to the eaves.
The span width for ridge conductors is approx. 15 m and for down conductors approx. 10 m without additional supports. Span stakes have to be fastened to the roof construction (rafters and crossbars) using anchor bolts and flat washers.
Today an isolated (HVI) lightning protection system is often used as an external lightning protection system for buildings with thatched roofs.
Air-termination conductors on thatched roofs have to be installed at a distance to the roof, e.g. on isolating supports. Certain distances also have to be kept to the eaves.
The span width for ridge conductors is approx. 15 m and for down conductors approx. 10 m without additional supports. Span stakes have to be fastened to the roof construction (rafters and crossbars) using anchor bolts and flat washers.
Today an isolated (HVI) lightning protection system is often used as an external lightning protection system for buildings with thatched roofs.
Wooden stake
Art.-Nr. 145241
HP 90X90 2400 EHI
item
Clamping cap
Art.-Nr. 146309
SPK 100X100 FSP10 300 7.10 V2A
item
Roof conductor support
Art.-Nr. 240000
DLS 6.10 134X300X598 EHI
item
Eaves supports St/tZn / StSt
Art.-Nr. 239000
TS 7.10 V1.0 1.15M STTZN
item
Eaves supports St/tZn / StSt
Art.-Nr. 239001
TS 7.10 V1.25 1.40M STTZN
item
Eaves supports St/tZn / StSt
Art.-Nr. 239009
TS 7.10 V1.25 1.55M V2A
item
Eaves supports St/tZn / StSt
Art.-Nr. 239019
TS 7.10 V1.45 1.75M V2A
item
Anchoring block
Art.-Nr. 241009
ASK 8 150 40 2XB10.5 V2A
item