Isolated lightning protection
Components made of glass-fibre-reinforced plastic (GRP) for erecting separate air-termination systems to maintain the separation distance.
DEHNiso Spacers
Variable holder range for conductors and air-termination rods for maintaining the separation distance according to DIN EN 62305-3 (VDE 0185-305-3).
Spacer bar made of glass-fibre reinforced plastic (GRP), Ø16 mm, UV-stabilised, light grey colour.
The DEHNiso spacers meet the requirements of DIN/IEC TS 62561-8.
Spacer bar made of glass-fibre reinforced plastic (GRP), Ø16 mm, UV-stabilised, light grey colour.
The DEHNiso spacers meet the requirements of DIN/IEC TS 62561-8.
Air-Termination Rods GRP/Al
For erecting isolated air-termination systems, e.g. on flat roofs, installed in a concrete base with fixing wedge.
The material factor km = 0.7 is used to determine the separation distance (length of spacer bar).
Diameter 16 mm, UV-stabilised, light grey colour, permanent temperature range -50 to +100 °C.
The GRP/Al air-termination rods meet the requirements of DIN/IEC TS 62561-8.
The material factor km = 0.7 is used to determine the separation distance (length of spacer bar).
Diameter 16 mm, UV-stabilised, light grey colour, permanent temperature range -50 to +100 °C.
The GRP/Al air-termination rods meet the requirements of DIN/IEC TS 62561-8.
DEHNiso Roof Conductor Holders
Variable range of holders for keeping the separation distance when installing conductors on flat roofs.
Spacer bar made of glass-fibre reinforced plastic (GRP) Ø10 mm, UV-stabilised, light grey colour
Spacer with concrete block and base plate, for conductors Rd 8 mm.
The DEHNiso roof conductor holders are tested in line with DIN/IEC TS 62561-8.
Spacer bar made of glass-fibre reinforced plastic (GRP) Ø10 mm, UV-stabilised, light grey colour
Spacer with concrete block and base plate, for conductors Rd 8 mm.
The DEHNiso roof conductor holders are tested in line with DIN/IEC TS 62561-8.
DEHNiso Combi Sets
Components for isolated air-termination systems.
For protecting large roof-mounted structures, e.g. air-conditioning systems, heat exchangers, etc.
For keeping the separation distance to electrically conductive parts according to IEC/EN 62305-3.
The separation distance (insulating clearance) is determined with material factor km = 0.7.
For protecting large roof-mounted structures, e.g. air-conditioning systems, heat exchangers, etc.
For keeping the separation distance to electrically conductive parts according to IEC/EN 62305-3.
The separation distance (insulating clearance) is determined with material factor km = 0.7.
Accessories for isolated lightning protection